Good-Lite 477702-Vergence Prism 6D BO & 2D BI with Handle Vergence Facility Prism 6D/2D
    Good-Lite 477702-Vergence Prism 6D BO & 2D BI with Handle Vergence Facility Prism 6D/2D
Good-Lite 477702-Vergence Prism 6D BO & 2D BI with Handle Vergence Facility Prism 6D/2D
Good-Lite 477702-Vergence Prism 6D BO & 2D BI with Handle Vergence Facility Prism 6D/2D
    Good-Lite 477702-Vergence Prism 6D BO & 2D BI with Handle Vergence Facility Prism 6D/2D
Good-Lite 477702-Vergence Prism 6D BO & 2D BI with Handle Vergence Facility Prism 6D/2D

About

Description

Vergence Facility  6D BO & 2D BI testing has been shown to be one of the most important methods of detecting patients with binocular vision disorders and symptoms. Diagnosis of non-strabismus binocular vision abnormalities can be improved through the use of vergence facility testing at near.

Testing Procedure:

The test is performed at 40 cm as the patient views a vertical 20/30 target or similar. Six diopter base out (BO)and two diopter base in (BI) prism are alternately placed before one eye; the patient is asked to report when the target becomes single and clear. This prism change is repeated for one minute and the clinician records the number of cycles performed during testing. The presence of suppression is indicated by a perceived lateral movement of a single target moving left or right of center, or no observed eye movement.

For testing at near, the recommended failure criteria are 15 cycles per minute which are easily recalled (sum of BI and BO demands). Recent research has shown this criterion is valid for pediatric, adult, and presbyopic populations.

Prisms Tech Bulletin

Description

Vergence Facility  6D BO & 2D BI testing has been shown to be one of the most important methods of detecting patients with binocular vision disorders and symptoms. Diagnosis of non-strabismus binocular vision abnormalities can be improved through the use of vergence facility testing at near.

Testing Procedure:

The test is performed at 40 cm as the patient views a vertical 20/30 target or similar. Six diopter base out (BO)and two diopter base in (BI) prism are alternately placed before one eye; the patient is asked to report when the target becomes single and clear. This prism change is repeated for one minute and the clinician records the number of cycles performed during testing. The presence of suppression is indicated by a perceived lateral movement of a single target moving left or right of center, or no observed eye movement.

For testing at near, the recommended failure criteria are 15 cycles per minute which are easily recalled (sum of BI and BO demands). Recent research has shown this criterion is valid for pediatric, adult, and presbyopic populations.

Prisms Tech Bulletin

Vergence Facility Prism 6D/2D

Regular price
$26.95
Sale price
$26.95
Regular price
$0.00
Shipping calculated at checkout.

Translation missing: en.products.product.sku:477702

Local and International Shipping
Shop with confidence and have your favorite products delivered right to your doorstep.
Our Product Satisfaction Guarantee
If you're not completely satisfied with your purchase, we’ll make it right!
Online Support 24/7
Get in touch with us anytime, anywhere, and let's get you sorted.
Regular Sales
Don't miss out on our amazing deals with regular sales on our cutting-edge products
Important Notice
This product can be purchased without a prescription. However, it is intended for use by, or under the guidance and supervision of, a qualified healthcare professional. By purchasing this product, you assume full responsibility for its appropriate use. Any questions, email: orders@good-lite.com

Check Out These Related Products